Skip to main navigation Skip to main content Skip to page footer

LAMBDA RTO

RTO - Regenerative Thermal Oxidation

LAMBDA's RTO systems ensure reliable and autothermal treatment of landfill gases with methane contents from around 1 % by volume. These systems correspond to the state of the art in accordance with VDI 3899 Sheet 1 and therefore fully meet the requirements for the thermal treatment of landfill lean gases.

Why customers rely on RTO systems from LAMBDA

The RTO systems are available in three standardized performance classes up to a firing capacity of 500 kW. During the development of the RTO systems, special focus was placed on the specific requirements for operation with landfill gas. In conjunction with a LAMBDA gas conveying station, typical operating modes can be implemented during in-situ stabilization with a high degree of automation and high availability.

Efficient use of the waste heat generated is possible with the optional "Therm" heat extraction module if a heat sink is available.

The Lambda RTO is characterized by the following features:
  • Future-proof: Autothermal operation even with very low methane content in the landfill raw gas.
  • Engineering: LAMBDA's RTO systems have been developed for typical landfill applications and differ from conventional systems for exhaust air treatment.
  • Operating costs: Optimized system design for low pressure losses and low power consumption.
  • Plant safety: Safety concept for the entire plant that has been tested by experts and is ready for acceptance.
  • Future-proof treatment of very low calorific value gases from landfill stabilization measures
Technical data:

Feature

RTO 100

RTO 250

RTO 500

Thermal load range (kWth)

20-100

50-250

100-500

Thermal control range

1:5

1:5

1:5

Treatable landfill gas volumes

at 10 vol.-% CH₄ (m³/h)

approx. 20-100

approx. 50-250

approx. 100-500

Treatable landfill gas volumes

at 2 vol.% CH₄ (m³/h)

approx. 100-500

approx. 250-1,250

approx. 500-2,500

Gas flow rate (m³/h)

2.000

5.000

10.000

CO₂e avoidance (t/a)

1.580

3.970

7.940

The RTO systems are available in three standardized performance classes up to a firing capacity of 500 kW. During the development of the RTO systems, special focus was placed on the specific requirements for operation with landfill gas. In conjunction with a LAMBDA gas conveying station, typical operating modes can be implemented during in-situ stabilization with a high degree of automation and high availability.

Efficient use of the waste heat generated is possible with the optional "Therm" heat extraction module and with an existing heat sink.

Downloads

RTO data sheet

LAMBDA RTO in 3D view

LAMBDA RTO in use:

Working together for a sustainable future!

Find out how our products and solutions can make your projects more economical, efficient, and environmentally friendly.
Contact us for further information or a personalized consultation.

Ich habe die Datenschutzrichtlinien und Nutzungsbedingungen von LAMBDA gelesen und stimme ihnen zu.

Pflichtfelder *